Double Effect Evapotator
- JOSTON
- WENZHOU, CHINA
- 35 DAYS
- 20 SETS/MONTH
it is a energy saving evaporator ,it compare with single effect evaporator ,it have the following advantage :
1)Can save 50% steam consumption
2)Can save 50% cooling water consumption
Double effect concentrator is suitable for low temperature vacuum concentration of heat sensitive materials such as traditional Chinese medicine, western medicine, glucose, wine making, starch, oral liquid, chemical industry, food, monosodium glutamate, dairy products, etc.
Double effect concentrator is used for evaporation and concentration of water /solvent. Double effect concentrator has simple structure, convenient operation and maintenance. The whole process is completed in a vacuum sealed system, and the heat energy is reused.
Double effect concentrator not only saves energy and protects the environment, but also has the advantages of low evaporation temperature and high evaporation intensity.
Double effect concentrator adopts double effect evaporation at the same time. The full utilization of the secondary steam not only saves the investment of the boiler, but also saves the energy consumption. Compared with the single effect concentrator, the energy consumption is reduced by 50%.
Double effect concentrator adopts external heating natural circulation and vacuum negative pressure mode, with fast evaporation speed and large concentration ratio. The liquid material has no foam concentration in the full sealing, and the concentrated liquid produced by the equipment has no pollution and strong flavour. Easy to clean
Double effect concentrator is including the following units first effect heating tank,first effect evaporator tank ,second effect heating tank ,second effect evaporator tank ,gas/water separator,condenser ,sub-cooler , collection tank .and pipeline .
Double effect concentrator Technology data Specification:
Model Item | SX500 | SX1000 | SX1500 | SX2000 | SX3000 |
Evaporate capacity kg/h
| 5000 | 1000 | 1500 | 2000 | 3000
|
First effect evaporated temperature C | 75-85 | ||||
Second effect evaporated temperature C | 55-65 | ||||
First effect heating area M2 | 6.2 | 12.2 | 18.5 | 24.4 | 37 |
Second effect heating area M2 | 6.2 | 12.2 | 18.5 | 24.4 | 37 |
Condenser cooling area M2 | 14 | 28 | 42 | 56 | 84 |
Sub-cooler cooling area M2 | 2 | 3 | 3 | 5 | 6 |
Steam consumption kg/h | 275 | 550 | 825 | 1100 | 1650 |
Cooling water consumption T/H | 16 | 30 | 45 | 50 | 90 |
Vacuum air absorption capacity m3/h | ≥125 | ≥250 | ≥375 | ≥500 | ≥750 |
Dimension :MM | 4800*1100*3750 | 5950*1200*4650 | 6300*1350*4750 | 6800*1550*4850 | 7500*1800*5800 |